BMQLP - LACQUER, ACRYLIC, LOW REFLECTIVE P956
- MSDS: BMQLP
- Manufacturer: LENMAR INC
- Product Name: LACQUER, ACRYLIC, LOW REFLECTIVE P956
- National Stock Number: 8010-01-042-9438
Product Identification
Product ID:LACQUER, ACRYLIC, LOW REFLECTIVE P956
MSDS Date:07/01/1991
FSC:8010
NIIN:01-042-9438
MSDS Number: BMQLP
Responsible Party
BALTIMORE, MD 21223
US
Emergency Phone: 301-358-5524
Info Phone: 301-947-2300
Cage: KO656
Contractor
Telephone: 410-947-2300/410-358-5524
Cage: 0BDY9
Ingredients
ETHANOL (ETHANOL) (VAPOR PRESSURE 43.9 MM HG @ 20 C)
CAS: 64-17-5
RTECS: KQ6300000
Fraction By Weight: 8.1%
OSHA PEL 1000 PPM
ACGIH TLV: 1000 PPM
N-BUTYL ACETATE (SARA 313) (BUTYL ESTER, ACETIC ACID)
CAS: 123-86-4
RTECS: AF7350000
Fraction By Weight: 16.9%
OSHA PEL 150 PPM
ACGIH TLV: 150 PPM
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
TOLUENE (SARA III)
CAS: 108-88-3
RTECS: XS5250000
Fraction By Weight: 7.7%
OSHA PEL 200 PPM/150 STEL
ACGIH TLV: 50 PPM; 9293
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
METHYL ETHYL KETONE (2-BUTANONE) (SARA 313) (VAPOR PRESSURE
CAS: 78-93-3
RTECS: EL6475000
Fraction By Weight: 23.6%
OSHA PEL 200 PPM
ACGIH TLV: 200 PPM
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
ISOPROPANOL (2-PROPANOL) (VAPOR PRESSURE 33 MM HG @ 20 C)
CAS: 67-63-0
RTECS: NT8050000
Fraction By Weight: 3.7%
OSHA PEL 400 PPM/500 STEL
ACGIH TLV: 400 PPM/500 STEL
TALC
CAS: 14807-96-6
RTECS: MW2700000
Fraction By Weight: 4.6%
OSHA PEL 0.2 FIBERS
ACGIH TLV: 0.2 FIBERS
6 OZ G/L.
RTECS: 9999999VO
Hazards
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:INHAL: ANESTHETIC. IRRIT OF RESP
TRACT/ACUTE NERVOUS SYS DEPRESS (HEADACHE/DIZZINESS/STAGGERING
GAIT/CONFUSION/UNCONSCIOUSNESS/COMA). SKIN/EYE: PRIMARY IRRIT.
REPEAT/PROLONG: PERM BRAIN/NERV SYS DAMAG E. CONC/INHALING MATERIAL
MAY BE HARMFUL OR FATAL. ANIMAL STUDIES: CARDIAC SENSITIZATION
(FATAL CHANGES IN HEART *
Explanation of Carcinogenicity:IARC HAS DETERMINED THAT THERE IS
LIMITED EVIDENCE FOR THE CARCINOGENICITY OF CRYSTALLINE SILICA TO
HUMANS.
Effects of Overexposure:*RHYTHMS. MASSIVE EXPOSURE MAY CAUSE MULTIPLE
ORGAN DAMAGE AND/OR DEATH. LONG TERM OVEREXPOSURE: TALCOSIS
(PULMONARY FIBROSIS) MAY LEAD TO SEVERE AND PERMANENT LUNG DAMAGE.
First Aid
First Aid:INHALATION: REMOVE TO FRESH AIR. IF BREATHING DIFFICULT, GIVE
OXYGEN. CALL DR. EYES: FLUSH IMMED W/COPIOUS QUANTITIES OF RUNNING
WATER FOR 15 MINS MINIMUM. SEE DR. SKIN: WASH AFFECTED AREAS IMMED
W/WA TER. REMOVE CONTAMINATED CLOTHING AND LAUNDER BEFORE REUSE.
CONSULT DR. INGESTION: CALL DR OR POISON CONTROL CENTER
IMMEDIATELY. IF CONSCIOUS GIVE ONE OR TWO GLASSES OF WATER. DO NOT
INDUCE VOMITING.
Fire Fighting
Flash Point Method:TCC
Flash Point:21.0F,-6.1C
Lower Limits:1.0
Extinguishing Media:FOAM, ALCOHOL FOAM, CARBON DIOXIDE, DRY CHEMICAL,
WATER FOG.
Fire Fighting Procedures:WATER MAY BE INEFFECTIVE(USE WATER SPRAY TO
COOL CLSD CNTNRS TO PREVENT EXPLOSION). AVOID UNNECESSARY EXPOSURE
TO FUMES. IF EXPOSED, GET IMMED MED AID. USE SCBA
Unusual Fire/Explosion Hazard:DECOMP PROD: TOXIC GASES. KEEP CNTNRS
TIGHTLY CLSD. ISOLATE FROM HEAT/IGNIT SOURCES. CLSD CNTNRS EXPLOD
W/HEAT. DO NOT APPLY TO HOT SURFACES. DONT MIX W/SOLVNTS
Accidental Release
Spill Release Procedures:REMOVE ALL IGNITION SOURCES. MOP UP SPILLS OR
ADD ABSORBANT.USE ADEQUATE VENTILATION. MOVE LEAKING CNTNRS
OUTDOORS, OBSERVING PRECAUTIONS W/REGARD TO FIRE, SPARK & FLAME
HAZARD. RUNOFF TO WATERWAY CRE ATES FIRE HAZARDS; NOTIFY FIRE &
HEALTHAGENCIES.
Handling
Handling and Storage Precautions:STORE IN WELL-VENTILATED WAREHOUSE.
KEEP OUT OF DIRECT SUNLIGHT/OTHER HEAT SOURCE. KEEP CONTAINERS
CLOSED. NO SMOKING. DO NOT INGEST (HARMFUL/FATAL).
Other Precautions:GROUND CNTNRS WHEN POURING. AVOID LIQ FREE FALL OF
OVER A FEW IN. CLOSE CNTNR AFTER USE/USE ORIG CNTNRS ONLY. AVOID
SKIN CONTACT/BREATH VAPORS. NO HEAT/INGNIT SOURCES. USE
NON-SPARKING TOOLS/EXPLO PRO OF EQUIP. USE ONLY W/ADEQUATE VENT.
Exposure Controls
Respiratory Protection:OPEN AREAS: MECH FILTER RESPIRATOR. RESTRCT
VENT: CHEM/MECH FILTER RESPIRATOR. CONFINED: AIRLINE RSPRTR/HOOD.
WEAR RSPRTR DURING/AFTER APPLICATION UNLESS VAPOR/MIST BELOW TLV.
FOLLOW RESPIRATOR MFR'S DIRECTIONS FOR RESPIRATOR USE.
Ventilation:USE APPROVED SPRAY BOOTH. PROVIDE GENERAL DILUTION/LOCAL
EXHST VENTILATION (VOL/PATTERN TO KEEP CONC BELOW TLV).
Protective Gloves:REQ FOR PROLONGED OR REPEATED CONTACT.
Eye Protection:SPLASH PROOF GOGGLES.
Other Protective Equipment:NONE REQUIRED.
Work Hygienic Practices:NONE REQUIRED.
Supplemental Safety and Health
NOTE TO DR: IF MORE THAN 2.0 ML PER KG HAS BEEN INGESTED & VOMITING HAS
NOT OCCURRED, EMESIS SHOULD BE INDUCED W/SUPERVISION. KEEP VICTIM'S
HEAD BELOW HIPS TO PREVENT ASPIRATION. IF SYMPTOMS (IE, LOSS OF
GAG REFLEX, CONVULSIONS OR UNCONSCIOUSNESS BEFORE EMESIS), CONSIDER
GASTRIC LAVAGE USING CUFFED ENDOTRACHEAL TUBE.
Chemical Properties
Boiling Pt:B.P. Text:173 TO 302F
Vapor Density:> AIR
Spec Gravity:8.81 LB/GL
Evaporation Rate & Reference:SLOWER THAN ETHER
Percent Volatiles by Volume:71
Stability
Stability Indicator/Materials to Avoid:YES
OXIDIZING AGENTS
Stability Condition to Avoid:TEMPERATURES IN EXCESS OF 150 F IN CLOSED
CONTAINER. EXPOSURE TO HEAT, SPARKS, OPEN FLAME AND HOT SURFACES.
Hazardous Decomposition Products:CARBON DIOXIDE, CARBON MONOXIDE
Disposal
Waste Disposal Methods:RECLAIM MATERIAL, INCINERATE OR USE SANITARY
LANDFILL METHOD OF DISPOSAL, IN ACCORDANCE WITH FEDERAL, STATE AND
LOCAL REGULATIONS. DO NOT INCINERATE CLOSED CONTAINERS. SEAL DRUMS
TIGHTLY.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.